italmanometri  

 
Pressure switch with NC contact Type 807 and coupler plug M12


  • Width across flats 24
  • Height 80
  • Length of thread 9

Pressure switch Type 807


 Type = reference number 807-1 807-10 807-20 807-100 807-200 807-100 K 807-200 K
 Range of adjustment, bar 0.2-1 1-10 2-20 10-100 20-200 10-100 20-200
 Overpressure safety 300 bar 600 bar
 Sealing element* diaphragm rotary seal
 Reproducibility ~ 5%
 Hysteresis ~ 5-10%
 Switching frequency 200/min
 Voltage, max. 250 volt
 Current, max. 2 amp.
 Type of protection IP 55
 Temperature, permissible -20° to +100° C
 Weight 0.09 kg
 Thread G 1/8", G 1/8" tap., NPT 1/8", G 1/4", M 10x1 tap., M 12x1.5
   

  • The functions breaking, making or changing relate to rising pressure.
  • * Please indicate medium in your order.

 